A CaMa-only tab between Histórico and Seguimiento shows how many patients of the cohort fall in
each BI-RADS category at a cut-off (GET /cama/analisis/indicadores?corte=), as the cohort API
publishes it. It is a descriptive count, not an incidence or a survival estimate.
- Loading, pending (404), unavailable (503), error and out-of-contract states; the answer is
validated as an aggregate (no patient rows, nothing published under the threshold).
- A suppressed category is drawn grey and says why; only a published category opens its patients
in Seguimiento ("Ver pacientes" or a click on its bar).
- The page keeps the selection while the user moves between tabs, clears it on a domain change, and
"Volver al análisis" returns to the analysis as it was, with the scroll and the focus on the
control that opened the list, and no new request.
- Tables and figure scroll inside their own region at phone width. CaCu and TEA keep their three
sections. Curves, the heatmap and the cohort diagnostics of the prototype wait for an API.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
The follow-up list of breast cancer can now be opened on a selection that the analysis names: the
whole cohort (window 0, offered only while the selection is active), the cut-off the analysis was
computed at, the group's filter, and the cohort with its revision, which the server requires and
repeats.
- A cohort's list quotes `cohorte`, `escenario` and `revision` (not filters) on every page and in the
export; an answer that loses a filter, changes the window or the cut-off, or is another cohort or
revision is not drawn and cannot be exported.
- A new selection cancels the previous request; while it loads, and when it fails (403, 409, 503),
no list of the previous query stays on screen.
- Inside the cohort the form refines the same cohort and says so; "Quitar selección" leaves it.
- "Volver al análisis" and a note when the list holds a different number of patients than the
analysis counted.
- PDF and XLSX state the selection, the cut-off and "Toda la cohorte"; the file name tells a
selection apart; an export in progress is cancelled, and a finished one discarded, when the query
on screen changes.
Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
CaMa header reads "Sistema TNM de clasificación tumoral" without the top subtitle.
The general filters block is titled "Filtros generales" and drops the scope
description and the applied-filter summary. In the Histórico the suppressed-data
text becomes a collapsed footnote (details/summary) with the same full text.
CaCu and TEA headers and filters are unchanged.
The rates figure lets the category labels size their own margin, shortens the
axis title, keeps few ticks and wraps «BI-RADS 4 sin subtipo» when the window is
600 px wide or less, and is redrawn when the window crosses that width. Values
and states are unchanged. The reading text keeps the capitals of a category
code inside a sentence («lesión de riesgo (B3)»).
CAM-01 and CAM-02 already had their KPI cards and history panels waiting for the
catalog; they are now covered with the answers WebApi gives for the synthetic
base, both visible (lowered suppression threshold) and suppressed (normal
threshold). Once published they draw only their KPI card in the summary, as the
mockup does, instead of an extra generic figure card; their evolution stays in
the history.
The stacked history figure now keeps a category the catalog announces even when
no row carries it, so a missing category is named under the figure instead of
silently disappearing. The integration specs also cover the summary and the
history with CAM-01, CAM-02 and CAM-03 published.
The card for cama_histopatologia_birads now shows rates with their Wilson
interval per BI-RADS category and a two-ring donut of the biopsy result, with
group and category selection, period navigation and the published values table.
A pure adapter turns the stratified C2 response into rows and figures; the view
only asks for the data and draws what the adapter returns.
BI-RADS 4 is a row of its own. The denominator is benign, B3, in situ and
invasive; no biopsy and no data are reported apart. A published zero is a zero,
a suppressed cell is suppressed, and a cell or stratum the response does not
carry is unavailable, never zero: no rate or donut total is drawn over an
incomplete matrix. The card keeps its place first in the summary and stays
pending while the catalog does not publish the indicator.
The `birads` stratum is added to the accepted dimensions of the data request.
The CaCu cytology confirmation view is not touched.
The tab asks GET /cama/seguimiento when it is first opened and draws the form,
the table, the details and the pagination from what the answer announces, so a
later change of source behind the endpoint needs no change here. It shows the
demonstration notice when the answer is simulated, a clear pending state while
the endpoint is not published (404 on the first page), and error, empty and
retry states. Stale requests are cancelled.
The sections, CaCu and initial-integration specs now expect the CaMa request
when the tab opens.
GET /<dominio>/seguimiento with the window, page, size, cut-off date and the filters the list announces. Filters and columns come with the answer; only demonstration answers (simulado: true) are accepted and anything outside the contract is rejected before it reaches a view. The fixture is the synthetic answer of the reference prototype and is used by tests only.
The kit's notes are no longer appended to CaMa's opportunity cards (they stay in the figure footers, Histórico and Datos y definiciones). The four cards measure 308 x 220 px at 1366 px, like the reference. TEA keeps its notes and CaCu already hid them.
Confirmation, screening-to-diagnosis and exam-to-result cards leave the summary (they stay in Histórico and Datos y definiciones). The histopathological result by BI-RADS keeps its place and structure as a pending card, with no figure or number, until the catalog publishes its indicator. The patients KPI uses the reference's wording.
Tokens are set on body when the indicators header is present, so menus, selects and dialogs share them; the other routes keep Rajdhani and their shapes.
(cherry picked from commit f5103b483d9d7188b4feffe91beda38d997004d4)
The menu and its overlay were in the initial bundle of every route (+183 kB); they now load in their own chunk, with a same-size placeholder. On phones the title moves to a second row instead of being squeezed beside the selector.
(cherry picked from commit 2ccddf80dbbe41a328281fcdc1c95ebe421f4191)
The in-page domain buttons are removed, since the header selector replaces them. Also fixes a computed that, after a visit to CaMa, never became true again, so CaCu and TEA lost their search box when switched to from CaMa.
(cherry picked from commit 3678c3653b33fcb98ba2334ca8f03f838dc86440)
On /indicadores/<dominio> the header shows «Plataforma de Indicadores» and a menu button with the current domain (TEA, CaCu, Cáncer de mama) that links to the other two through the router. Institutional routes keep their breadcrumb header.
(cherry picked from commit 79a18fd7a8ed1a3a58201e7cc24c9692b53dbc47)
A Histórico tab between Resumen and Seguimiento, for CaMa only: monthly or semestral interval, how many periods to show, and a custom period dialog. Counts are stacked, rates draw their confidence band and medians their quartile band; suppressed periods are shaded and listed, and a rate over no denominator or a median over no observations is no value. Five charts use published indicators; the three whose indicator the catalog does not publish are drawn as pending panels.
(cherry picked from commit 268d7443e0a89da8d6bc67ecb2b5db2715236f93)
One card draws the exams by category as a donut and, per BI-RADS family, the patients next to the exams. Patients come from cama_birads_456_paciente (each patient once per period, in the category of the most severe exam), so its exclusive categories are added within that indicator only, for the verified version 0.2.0; other versions, suppressed or missing cells leave the figure unknown. No exams-per-patient ratio is computed and patients are never derived from exams. The patients' indicator has no card of its own while the exams' one is published.
(cherry picked from commit b7bafd178896cb2715049d5c8293185f31391c92)
CaMa's graphic section reads «Indicadores clínicos» and counts the indicators it draws. The search box, pins, floating navigation, representation selector and figure count are not drawn for CaMa; CaCu and TEA keep them.
(cherry picked from commit e54ee5a55aa3722f6895300fa7e8cefb28f12ebb)
CaMa reads «cáncer de mama» everywhere on the indicators page and uses the compact filter: interval, one period and Aplicar on one row, without the mode selector, the multiple selection or the editing summaries. The opportunity strip is the four cards only, and the biopsy distribution card is no longer drawn in the summary (it stays in Datos y definiciones). Other domains keep their filter and strip.
(cherry picked from commit 7c9dcf634e5870fec35ab96347b0863b2e3bb86e)
Cards: patients with BI-RADS 4, 5 and 6, histopathological detection rate, screening to result and result to diagnosis times. The detection rate and the result-to-diagnosis time are not published by the catalog yet, so they are drawn as explicit pending cards and are queried once the catalog lists them. cama_eu38a is added to the CaMa KPIs.
Las tablas desplegables decían «Valores publicados y celdas suprimidas» o «… y cajas no disponibles», que confundía: ahora dicen «Valores publicados». La tabla de contingencia de citología y biopsia estaba siempre a la vista; ahora va plegada bajo «Valores publicados», como las demás. Registrado en docs/bitacora-textos.md.
CSO5.5
El método estadístico y los campos nuevos de la ficha se posponen; los textos dirán «calidad de espécimen satisfactoria» y la consulta se alineará después.
CSO5.5
«Sin resultado válido en el periodo» no decía qué es un resultado válido. La nota ahora dice «con resultado no disponible o de calidad de espécimen insatisfactoria a la fecha de corte», que es lo que cuenta la consulta. Registrado en docs/bitacora-textos.md.
CSO5.5
CaCu es el nombre que le dimos nosotros, no el que busca un médico. Las etiquetas de la página dicen «cáncer cervicouterino», con mayúscula donde abre el texto (la línea «Cáncer cervicouterino, investigación», que ya no dice «Dominio»). El botón del encabezado para cambiar de proyecto sigue diciendo «CaCu», provisional; las direcciones no cambian (/indicadores/cacu). El encabezado dice «Indicadores» en lugar de «Dashboard de indicadores» y el subtítulo «Explora los indicadores de …» sin mencionar el servicio de reportes. «Datos y definiciones» ya no repite «Dominio: …» bajo su título. TEA y CaMa conservan su nombre. Registrado en docs/bitacora-textos.md.
CSO5.5
Las tarjetas de indicadores de oportunidad de CaCu mostraban, después de su línea, las notas del kit (el pie de las figuras): repetían la definición y, en los tiempos, hablaban de la caja. Ahora dicen solo su línea: «Pacientes con citología tomada en el periodo.» y «n citologías; primer cuartil: x días; tercer cuartil: y días.», sin Q1 ni Q3. El número de Pacientes evaluadas no cambia; «Datos y definiciones» de CaCu aclara que incluye las citologías con espécimen insatisfactorio. TEA y CaMa no cambian. Registrado en docs/bitacora-textos.md.
CSO5.5
La sección general de advertencias al final de Datos y definiciones repetía avisos genéricos (nulos, periodos, intervalos, uso para investigación) que no son de ningún indicador y solo agregaban ruido; la interpretación de cada gráfica está en su botón Cómo leer. Se quita solo la sección de la plantilla y la aserción de la prueba que buscaba su texto.
CSO5.5
El kit no cambia el formato del pie de las figuras: sigue publicando «<fuente> · Fecha de corte: AAAA-MM-DD» y la misma fuente de TEA. Se revierten la expresión regular que valida el pie de TEA, la extracción de la fecha de corte bajo la gráfica, los fixtures sintéticos y sus specs a como estaban. El cambio de textos de pantalla queda solo en los literales que se muestran o se leen en aria-label, sin tocar la lógica que compara o valida.
CSO5.5
Los textos que ve una persona, visibles o en aria-label, ya no usan flechas ni rayas o puntos medios como separador: se separan con comas o se reescribe la frase (por ejemplo «Días de toma a resultado (laboratorio)», «Último dato visible, 2025-S1», «Dominio CaCu, investigación», «2025-S2, 1 de 3» o «Datos y definiciones de CaCu»). El pie que publica el kit cambia al mismo estilo, así que la validación del pie de TEA y la lectura de la fecha de corte reconocen el formato nuevo con comas y siguen aceptando el anterior para no romper con un kit previo. Se ajustan los fixtures sintéticos y las specs a los textos nuevos.
CSO5.5
La tabla de resumen repetía en formato largo los valores de todas las figuras; cada figura ya trae su propia tabla de valores. Se quitan el componente indicadores-numeric-summary y sus filas (indicadores-numeric-rows), y las pruebas que dependían de ellos.
CSO5.5
El filtro general y sus mensajes de compatibilidad nombran «Intervalo de tiempo» (semestre o mes) en lugar de «Granularidad», que no es un término clínico. Cambian la etiqueta del selector y los cinco mensajes que la mencionan; las pruebas que citaban esos textos se ajustan.
CSO5.5
Las reglas de cálculo que publica el kit en `parametros` (clave, valor, estado y fuente) irán en un apéndice o manual técnico aparte, no en la pestaña «Datos y definiciones». Se quita la tabla «Reglas» y su formato de valores, y la pestaña conserva la ficha técnica, las referencias y las poblaciones. También se retiran el tipo y la validación estricta de `parametros` en el servicio: ya nadie los usa y una lista mal formada bloqueaba los metadatos completos. Si el servidor envía `parametros`, se ignoran.
CSO5.5
Agrega el panel de tasa de confirmación histopatológica (cacu_confirmacion_citologia): tasas por resultado citológico de alto grado con su intervalo de Wilson a la izquierda, dona del grado de biopsia a la derecha y tabla de contingencia; la vista base es «LIEAG o más» y las pacientes sin biopsia aún no entran al denominador. Une en una sola figura los tiempos de toma a resultado (pedido por id, oculto en el catálogo) y de toma a diagnóstico. La pestaña Datos y definiciones muestra la ficha técnica y las reglas del kit en tablas; las notas de cada figura pasan a su Cómo leer, las tarjetas dejan solo valor, n y periodo, y el Cómo leer de EU7 muestra solo lo que publica el kit. Las transiciones animadas quedan fuera, como entrega aparte para el diseñador.
CSO5.5